Re: problem with IsapiModule in IIS 7

$
0
0
Re: problem with IsapiModule in IIS 7
Web Connection 5.0
Re: problem with IsapiModule in IIS 7
04/23/2012
09:16:16 PM
3HI19LCVB Show this entire thread in new window
Gratar Image based on email address
From:
Rick Strahl
To:
Attachments:
None

What version of Web Connection are you configuring with? Latest version should just work and it sets most of important settings.

All of this should be automatic but:

* Make sure that the application pool is set to run 32 bit apps
* Make sure the web.config entry points at the right file on disk

+++ Rick ---

+++ Rick ---



Hi All, I recently ran the install for web connect demo on a 2008 server in hopes that it would config everything just right, and run the the samples page w/o a hitch. I did however, get the sample default.htm to run, but when I click a link I get an error suggesting there is an issue with module list and our ISAPI wc.dll.... is this something that might be fixed w/o too much problem? I'm sure it has to do with web.config somehow, but not sure where to start. Thanks in advance for any thoughts on this!

Matt

HTTP Error 500.21 - Internal Server Error
Handler "AboMapperCustom-15949230" has a bad module "IsapiModule" in its module list
Detailed Error Information
Module IIS Web Core
Notification ExecuteRequestHandler
Handler AboMapperCustom-15949230
Error Code 0x8007000d
Requested URL http://localhost:80/wconnect/wc.wc?_maintain~ShowStatus
Physical Path C:\inetpub\wwwroot\wconnect\wc.wc
Logon Method Anonymous
Logon User Anonymous



Rick Strahl
West Wind Technologies

Making waves on the Web